December 16, 2019

Lennox HS29-141 Heat Pump Page1 HS29 ServiceLiterature HS29SERIESUNITS

Lennox HS29-141 Heat Pump Page1 HS29 ServiceLiterature HS29SERIESUNITS - page 1

Page 1

¤1998 Lennox Industries Inc.

&RUS /

HS29

Service Literature

HS29 SERIES UNITS

The HS29 is a residential split-system condensing

unit. Condensing coil size, circuiting and air volume

result in a minimum SEER rating of 10.0. The series is

designed for use with an expansion valve or RFCIV

system in the indoor unit. However, the HS29–651

and –060 use only the TXV system.

The HS29–141 and –012 utilizes a rotary compressor. Oth-

er HS29 units (–018, –024 and –211 through –653) utilize a

reciprocating compressor. All compressors are hermeti-

cally sealed for trouble-free operation and long service

life. Compressor components are spring-mounted within

the sealed housing. The compressor is installed in the

unit on resilient rubber mounts to assure quiet, vibration-

free operation. A built-in protection device assures

protection from excessive current and tempera-

tures.

HS29–460 through HS29–650 models are furnished

with crankcase heaters to assure proper compressor

lubrication at all times. The heater is temperature-

actuated and operates only when required.

HS29–030 through –060 units utilize a scroll compressor.

The scroll operates like a standard compressor but it is

unique in the way it compresses refrigerant.

Several models are available in sizes ranging from 1

through 5 tons.

This manual is divided into sections which discuss

the major components, refrigerant system, charging

procedure, maintenance and operation sequence.

All specifications in this manual are subject to

change.

SPECIFICATIONS

Model No.

HS29-141

HS29-211

HS29-261

HS29-311

Net face area sq ft (m

2

)

Outer coil

7.56 (0.70)

11.33 (1.05)

11.33 (1.05)

13.22 (1.23)

Condenser

Net face area - sq. ft. (m

2

)

Inner coil

- - - -

- - - -

- - - -

- - - -

Condenser

Coil

Tube diameter — in. (mm) & no. of

rows

5/16 (7.9) — 1

5/16 (7.9) — 1

5/16 (7.9) — 1

5/16 (7.9) — 1

Fins per inch (m)

22 (866)

22 (866)

22 (866)

22 (866)

Diameter — in. (mm) & no. of blades

18 (457) — 3

18 (457) — 3

18 (457) — 3

18 (457) — 3

Motor hp (W)

1/6 (124)

1/6 (124)

1/6 (124)

1/6 (124)

Condenser

Fan

Cfm (L/s)

2400 (1135)

2400 (1135)

2400 (1135)

2460 (1160)

Fan

Rpm

1105

1105

1105

1125

Watts

180

180

180

170

*Refrigerant charge furnished (HCFC-22)

2 lbs. 12 oz.

(1.25 kg)

3 lbs. 10 oz.

(1.64 kg))

3 lbs. 13 oz.

(1.73 kg))

4 lbs. 5 oz. (1.96 kg)

Liquid line — in. (mm) o.d. connection (sweat)

a3/8 (9.5)

a3/8 (9.5)

a3/8 (9.5)

a3/8 (9.5)

Suction line — in. (mm) o.d. connection (sweat)

5/8 (15.9)

5/8 (15.9)

5/8 (15.9)

3/4 (19.1)

Shipping weight — lbs. (kg) 1 package

146 (66)

146 (66)

148 (67)

157 (71)

*Refrigerant charge sufficient for 20 ft. (6.1 m) length of refrigerant lines.

a3/8×5/16 in. (9.5×7.9mm) adaptor furnished for liquid line connection.





Page 1 ¤1998 Lennox Industries Inc. &RUS / HS29 Service Literature HS29 SERIES UNITS The HS29 is a residential split-system condensing unit. Condensing coil size, circuiting and air volume result in a minimum SEER rating of 10.0. The series is designed for use with an expansion valve or RFCIV system in the indoor unit. However, the HS29–651 and –060 use only the TXV system. The HS29–141 and –012 utilizes a rotary compressor. Oth- er HS29 units (–018, –024 and –211 through –653) utilize a reciprocating compressor. All compressors are hermeti- cally sealed for trouble-free operation and long service life. Compressor components are spring-mounted within